Constant Pressure Inverter Control System

Applications

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.

Product Features

The pump will start smoothly when water is consumed. The inverter controller has a pressure sensor to detect down-stream pressure and adjust the motor speed to keep it at the required psi.

Constant and stable pressure control

The pump will maintain a constant operating pressure at the pressure setting. This ensures a stable water supply even though occasionally the output .ow is over the capacity.

Dry-run protection

The pump will automatically shut down to protect against dry running. Once the pump starts to operate, the pressure sensor will automatically detect the pressure limit.

Automatic stop when flow stops

The pump will automatically cycle down as water usage decreases.

Pressure compensation for pipeline leaks

Should the down steam pressure drop due to leaks in the piping system, the microcomputer will detect the pressure loss automatically and operate the pump to maintain the pressure setting limit.

Single or parallel unit operation

Parallel operation: When water usage is low, one unit will begin to operate until the water usage increases, when it can no longer handle the required water pressure, the other unit will start functioning in parallel. The duplex unit will switch to single unit operation automatically with the decrease in water demand.

Interchangeable operation

When a pump has operated through the preset interval (adjustable at 0-24 hours) the system will automatically switch to the other unit. This cycle will continue through time.

Operation Condition

Ambient temperature:Max. +40°C

Liquid temperature:+4°C~+75°C

Suitable liquids:Potable water or other clean, thin or non-aggressive liquids

Inlet pressure: Lower than the constant pressure setting limit (see page 03~08)

System Pressure:Max.10kg/cm²

TPHIC

Compare Products

Type
TPH2T2KIC
TPH2T3KIC
TPH2T4KIC
TPH2T5KIC
TPH2T6KIC
TPH4T2KIC
TPH4T3KIC
TPH4T4KIC
TPH4T5KIC
TPH4T6KIC
TPH8T2KIC
TPH8T3KIC
TPH8T4KIC
TPH8T5KIC
TPH12T2KIC
TPH12T3KIC
TPH12T4KIC
TPH25T2KIC
TPH25T3KIC
TPH25T4KIC
TPH25T5KIC
TPH25T6KIC
Type Inverter Controller Output Power
(HP)
Phase
(Ø)
Volts
(V)
No-Fuse Breaker Pre-set Pressure
(kg/cm²)
Inlet
(in.)
Outlet
(in.)
Nominal Set Head
(M)
Nominal Set FLow
(L/min)
TPH2T2KIC 1 13 200-240V200-240V or 380-440V 2.0 1 1 20 30
TPH2T3KIC 1 13 200-240V200-240V or 380-440V 3.0 1 1 30 30
TPH2T4KIC 1 13 200-240V200-240V or 380-440V 4.0 1 1 40 30
TPH2T5KIC 1 13 200-240V200-240V or 380-440V 5.0 1 1 50 30
TPH2T6KIC 1 13 200-240V200-240V or 380-440V 6.0 1 1 60 30
TPH4T2KIC 1 13 200-240V200-240V or 380-440V 2.0 20 60
TPH4T3KIC 1 13 200-240V200-240V or 380-440V 3.0 30 60
TPH4T4KIC 2 13 200-240V200-240V or 380-440V 4.0 40 60
TPH4T5KIC 2 13 200-240V200-240V or 380-440V 5.0 50 60
TPH4T6KIC 2 13 200-240V200-240V or 380-440V 6.0 60 60
TPH8T2KIC 1 13 200-240V200-240V or 380-440V 2.0 2 2 20 130
TPH8T3KIC 2 13 200-240V200-240V or 380-440V 3.0 2 2 30 130
TPH8T4KIC 3 13 200-240V200-240V or 380-440V 4.0 2 2 40 130
TPH8T5KIC 3 13 200-240V200-240V or 380-440V 5.0 2 2 50 115
TPH12T2KIC 2 13 200-240V200-240V or 380-440V 2.0 2 2 20 230
TPH12T3KIC 3 13 200-240V200-240V or 380-440V 3.0 2 2 30 230
TPH12T4KIC 5 3 200-240V or 380-440V 4.0 2 2 40 230
TPH25T2KIC 5 3 200-240V or 380-440V 2.0 3 3 20 415
TPH25T3KIC 5 3 200-240V or 380-440V 3.0 3 3 30 415
TPH25T4KIC 3 200-240V or 380-440V 4.0 3 3 40 415
TPH25T5KIC 10 3 200-240V or 380-440V 5.0 3 3 50 415
TPH25T6KIC 10 3 200-240V or 380-440V 6.0 3 3 60 415

Dimensions (mm)

TPH2T/4T

TPH2T/4T - IC

Model A B C D E H Pressure tank(L)
TPH2T2KIC 306 114 99 90 267 357 0.8
TPH2T3KIC 324 132 117 90 267 357 0.8
TPH2T4KIC 342 150 135 90 267 357 0.8
TPH2T5KIC 400 168 153 90 267 357 0.8
TPH2T6KIC 418 186 171 90 267 357 0.8
TPH4T2KIC 315 123 108 90 238 328 0.8
TPH4T3KIC 382 150 135 90 238 328 0.8
TPH4T4KIC 409 177 162 90 238 328 0.8
TPH4T5KIC 436 204 189 90 238 328 0.8
TPH4T6KIC 494 231 216 90 238 328 0.8

TPH2T/4T - ICV

Model A B C D E H Pressure tank(L)
TPH2T2KICV 589 114 99 130 181 596 0.8
TPH2T3KICV 607 132 117 130 181 596 0.8
TPH2T4KICV 625 150 135 130 181 596 0.8
TPH2T5KICV 643 168 153 130 181 596 0.8
TPH2T6KICV 661 186 171 130 181 596 0.8
TPH4T2KICV 598 123 108 130 153 596 0.8
TPH4T3KICV 625 150 135 130 153 596 0.8
TPH4T4KICV 652 177 162 130 153 596 0.8
TPH4T5KICV 679 204 189 130 153 596 0.8
TPH4T6KICV 706 231 216 130 153 596 0.8
TPH8T/12T
Model A B C D E H Pressure tank(L)
TPH8T2KIC 603.5 128.5 75 151 235 625 4
TPH8T3KIC 635 160 107 151 235 625 4
TPH8T4KIC 635 160 107 151 235 625 4
TPH8T5KIC 669 194 141 151 235 625 4
TPH12T2KIC 603.5 128.5 75 151 235 625 4
TPH12T3KIC 635 160 107 151 235 625 4
TPH12T4KIC 635 160 107 151 235 625 4
TPH25T

TPH25T2KIC/TPH25T3KIC

Model A B C Pressure tank(L)
TPH25T2KIC 821 231 118 4
TPH25T3KIC 881 291 178 4

TPH25T4KIC~TPH25T6KIC

Model A B C Pressure tank(L)
TPH25T4KIC 596 178 57 4
TPH25T5KIC 706 238 117 4
TPH25T6KIC 706 238 117 4
 

i.Catalog

Catalog

TPHIC Series Constant Pressure Inverter Control System

Updated on 2024/04/16

1.68 MB

ii.Instruction Manual